Type | Hot Coaxial | |
Channels | 2 | |
Polarization | LHC-RHC | LHC-RHC |
Central frequency (GHz) | 2.28 | 8.58 |
Noise temperature | 120 | 110 |
Useful RF band (GHz) | 2.20÷2.36 | 8.18÷8.58 |
RF filter width (MHz) | 160 | 400 |
IF filter width (MHz) | 160 | 400 |
Instantaneous RF band (GHz) | 2.20÷2.36 | 8.18÷8.58 |
LO frequency (GHz) | 2.020 | 8.080 |
LO range (GHz) | 0 | 0 |
Conversion (GHz) | Single
USB
0.18÷0.34 |
Single
USB
0.1÷0.5 |
Standard parameters of the 2.3-8.3 GHz coaxial receiver
It is possible to use the receivers both together (coaxial, 2 IF outputs, one per each frequency) and separately (2 IF outputs). For the VLBI coaxial observation one channel only for each receiver is used, typically the right hand circular polarized one (this because the Mark IV can handle only 2 IF inputs).